Prepare the hood, Install the hood, Ape1 series page 3 – Broan APE1 User Manual
Page 3: Warning
APE1 SERIES
Page 3
PREPARE THE HOOD
4
Blower is shipped in Vertical Discharge Position.
To change blower to
Horizontal Discharge Position:
Remove
Knurled Nuts from Blower Mounting Rods.
Disengage mounting rods from blower and rotate blower
to horizontal discharge position. Re-engage mounting
rods and tighten blower in place with knurled nuts.
3
Remove the
Aluminum Filters, Bottom Cover, and
Wiring Cover from the hood.
ALUMINUM
FILTERS
BOTTOM
COVER
WIRING
COVER
VERTICAL DISCHARGE POSITION
HORIZONTAL DISCHARGE POSITION
BLOWER
MOUNTING
ROD (2)
KNURLED NUT (2)
BLOWER
MOUNTING
ROD (2)
KNURLED NUT (2)
BLOWER
BLOWER
5
Remove
Vertical Duct Knockout or Horizontal Duct
Knockout and attach Damper / Duct Connector with
two (2) screws (supplied).
VERTICAL DUCT
KNOCKOUT
HORIZONTAL DUCT
KNOCKOUT
DAMPER /
DUCT
CONNECTOR
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
6
Run
House Power Cable between service panel and
hood location. Attach power cable to hood using appropri-
ate connector.
7
Hold the hood in position under the cabinet. Make sure
the damper / duct connector enters the
Ductwork and
that the damper opens and closes freely.
8
Tighten the four (4)
Mounting Screws completely to se-
cure the hood to the cabinet.
HOUSE
POWER
CABLE
MOUNTING
SCREWS (4)
DUCTWORK