Wsw07 dial tone setting 1 v-20 – Brother FAX-921 User Manual
Page 113

V - 20
WSW07
(Dial tone setting 1)
Selector
No.
Function
Setting and Specifications
1
2
Frequency band range
No. 1 2
0 0
: Narrows by 10 Hz
0 1
: Initial value
1 X
: Widens by 10 Hz
3
Line current detection
0: No
1: Yes
4
|
6
2nd dial tone detection level
(Z = 600
Ω
)
No. 4 5 6
0
0 0 : -21 dBm
0
0 1 : -24 dBm
0
1 0 : -27 dBm
0
1 1 : -30 dBm
1
0 0 : -33 dBm
1
0 1 : -36 dBm
1
1 0 : -39 dBm
1
1 1 : -42 dBm
7
1st dial tone interrupt detecting
time
0: 30 ms
1: 50 ms
8
Not used.
NOTE: The WSW07 is not applicable in those countries where no dial tone or line current detection is
supported, e.g., U.S.A.
l
Selectors 1 and 2: Frequency band range
These selectors set the frequency band for the 1st dial tone and the busy tone (before dialing) to be
detected.
This setting is effective only when selectors 1 through 3 of WSW05 are set to “1,1,1.”
l
Selector 3:
Line current detection
This selector determines whether or not the equipment should detect a line current before starting
dialing.
l
Selectors 4 through 6:
2nd dial tone detection level
These selectors set the detection level of the 2nd dial tone.
l
Selector 7:
1st dial tone interrupt detecting time
This selector sets the allowable time length of an interrupt which should not be interpreted as an
interrupt in the 1st dial tone dialing.