beautypg.com

Wsw04 transfer facility setting v-15 – Brother FAX-921 User Manual

Page 108

background image

V - 15

WSW04

(TRANSFER facility setting)

Selector

No.

Function

Setting and Specifications

1

Earth function in transfer facility

0: Provided

1: Not provided

2

3

Dual tone detection frequency in
ICM recording

No. 2 3

0 0

:

350 and 440 Hz (A)

0 1

: 440 and 480 Hz (B)

1 x

: 480 and 620 Hz (C)

4

Tone detection sensitivity in ICM
recording

0: OFF

1: High

5

6

Earth time length for earth
function

No. 5 6

0 0

:

200 ms

0 1

:

300 ms

1 0

:

500 ms

1 1

:

700 ms

7

8

Break time length for flash
function

No. 7 8

0 0

:

80 ms

0 1

:

110 ms

1 0

:

250 ms

1 1

:

500 ms

NOTE: Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.

NOTE: Selectors 2 through 4 are applicable to those models equipped with a built-in TAD.

NOTE: Selectors 2 and 3 are applicable in the U.S.A.

l

Selector 1:

Earth function in transfer facility

This selector determines whether or not the earth function is added to the transfer setting menu to
be accessed by the function switch.

l

Selectors 2 and 3: Dual tone detection frequency in ICM recording

If the equipment detects either of the frequencies set by these selectors in ICM recording, it will
disconnect the line. For example, if these selectors are set to “0, 0,” the equipment will disconnect
the line upon detection of 350 Hz or 440 Hz.

l

Selectors 4: Tone detection sensitivity in ICM recording

Setting this selector to “1” increases the tone detection sensitivity in ICM recording.

l

Selectors 5 and 6: Earth time length for earth function

These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground.

This setting is effective only when the earth function is selected for the R key by using the function
switch.

l

Selectors 7 and 8: Break time length for flash function

These selectors set the break time length.

This setting is effective only when the flash function is selected for the R key by using the function
switch.

This manual is related to the following products: