Troubleshooting, Installation – AEG HC412000GB User Manual
Page 25
7. TROUBLESHOOTING
Problem
Possible cause
Remedy
There is no spark when
lighting the gas
• There is no electrical
supply
• Make sure that the
unit is connected and
the electrical supply is
switched on.
• Control the fuse. If the
fuse is released more
than one time, refer to
a qualified electrician.
• Burner cap and crown
are placed uneven
• Make sure that the
burner cap and crown
are in correct posi-
tions.
The flame is blow out im-
mediately after ignition
• Thermocouple is not
heated sufficient
• After lightning the
flame, keep the knob
pushed for approxi-
mately 5 seconds.
The gas ring burns un-
evenly
• Burner crown is
blocked with food resi-
dues
• Make sure that the in-
jector is not blocked
and the burner crown
is clear of food parti-
cles.
If there is a fault, first try to find a solu-
tion to the problem yourself. If you can-
not find a solution to the problem your-
self, speak your dealer or the local Serv-
ice Force Centre.
If you operated the appliance in-
correctly, or the installation was
not carried out by a registered
engineer, the visit from the cus-
tomer service technician or deal-
er may not take place free of
charge, even during the warranty
period.
8. INSTALLATION
WARNING!
Refer to the Safety chapters.
Before the installation, note
down the serial number (Ser. Nr.)
from the rating plate.The rating
plate of the appliance is on its
lower casing.
Made in Switzerland
Qn (Hs): 5 kW
Butan: 329 g/h
AC 220-240 V 50/60 Hz
P<0,025 kW
Adjusted for: G20 2H 2E 2E - 20 mbar
Typ: 55 WOK 04 GA
Mod.: HC411520GB
Serie-Nr:
PNC: 941 560 809/00
PIN 0063CL3461
10
0063
ENGLISH
25