Kramer Electronics FC-41 User Manual
Page 18
FC-41 - Communication Protocol
15
The following table defines the local parameter data:
Local Parameter Number
Local Parameter Data
Description
#
Input Standard
01
0 - 720p/60
1 - 720p/59
2 - 720p/50
3 - 1080i/60
4 - 1080i/59
5 - 1080i/50
6 - 1080p/30
7 - 1080p/29
8 - 1080p/25
9 - 1080p/24
A - 1080p/23
B - 1080sf/30
C - 1080sf/29
D - 1080sf/25
E - 1080sf/24
F - 1080sf/23
Mode Input Standard
02
0 - Auto
1 - Forced
SYNC Type
04
0 - Bi-Level
1 - Tri-Level
Test Signal
05
0 - NO TEST SIGNAL
1 - COLOR BAR 100%
2 - Y-SWEEP 30 MHZ
3 - PULSE 2T AND BAR
4 - Y-RAMP
5 - C-SWEEP 15 MHZ
6 - RAINBOW
7 - GRID
8 - GRID INVERSE
Black
08
-32% - +31% (1% step)
Y-gain
09
-64% - +63% (1% step)
Gain
0A
-64% - +63% (1% step)
Color
0B
-64% - +63% (1% step)
B-Y
0C
-64% - +63% (1% step)
R-Y
0D
-64% - +63% (1% step)
Sharpness
0E
0% - +150% (10% step)