Command List

Responses for commands and inquiries

ACK message

Returned by the EVI-D100/P when it receives a
command. No ACK message is returned for
inquiries.

Completion message

Returned by the EVI-D100/P when execution of
commands or inquiries is completed. In the case of
inquiry commands, it will contain reply data for the
inquiry after the 3rd byte of the packet. If the ACK
message is omitted, the socket number will contain a
0.

Reply Packet

Note

Ack

X0 4Y FF

Y = socket number

Completion (commands)

X0 5Y FF

Y = socket number

Completion (Inquiries)

X0 5Y ... FF

Y = socket number

X = 9 to F: EVI-D100/P address + 8

Error message

When a command or inquiry command could not be
executed or failed, an error message is returned
instead of the completion message.

Error Packet

Description

X0 6Y 01 FF

Message length error (>14 bytes)

X0 6Y 02 FF

Syntax Error

X0 6Y 03 FF

Command buffer full

X0 6Y 04 FF

Command cancelled

X0 6Y 05 FF

No socket (to be cancelled)

X0 6Y 41 FF

Command not executable

X = 9 to F: EVI-D100/P address + 8, Y = socket number

Socket number

When command messages are sent to the EVI-D100/P,
it is normal to send the next command message after
waiting for the completion message or error message
to return. However to deal with advanced uses, the
EVI-D100/P has two buffers (memories) for
commands, so that up to two commands including the
commands currently being executed can be received.
When the EVI-D100/P receives commands, it notifies
the sender which command buffer was used using the
socket number of the ACK message.
As the completion message or error message also has a
socket number, it indicates which command has ended.
Even when two command buffers are being used at
any one time, an EVI-D100/P management command
and some inquiry messages can be executed.
The ACK message is not returned for these commands
and inquiries, and only the completion message of
socket number 0 is returned.

Command execution cancel

To cancel a command which has already been sent,
send the IF_Clear command as the next command. To
cancel one of any two commands which have been
sent, use the cancel message.

Cancel Packet

Note

Cancel

8X 2Y FF

Y = socket number

X = 1 to 7: EVI-D100/P address, Y = socket number

The Command canceled error message will be returned
for this command, but this is not a fault. It indicates
that the command has been canceled.