Testing the Components
Check for Leaks
• Turn on the water supply and inspect all joints for leaks.
• Close the drain valve(s), fill the sink(s) with water and inspect the
drain fittings for leaks.
• Open the drain valve(s) and inspect the drain joins for leaks as the
water is draining from the sink.
Check the Electrical Installation
• Verify that there are no loose wires or open electrical enclosure.
• Fill the wash sink with water and press the START button to see that
the motor will start. Have a qualified electrician verify that the amp
draw on the electrical supply is within the specifications on the
identification tag.
• Check motor rotation for the correct direction as indicated by the
arrow on the pump housing.
Check Operation
• Open each faucet knob and verify that water flows from each hand
control. Verify that hot and cold water are running from the correct
hand control.
• With the sink full of water, skewers in the rack and the motor
running, verify that skewer rack rotates gently with the water flow.
• With the water valves open, turn the center knob to see that it will
shut off flow to the faucet and that the hand sprayer is still
functional.
Check the Chemical Dispensing System
The Chemical Dispensing System must be checked by a representative of
the manufacturer. It will need to be verified that the proper amount of
chemical is being dispensed and that the proper chemical concentration is
maintained during operation.
MOTOR ROTATION
MUST BE THE
CORRECT DIRECTION
FOR THE MACHINE TO
OPERATE CORRECTLY
IMPORTANT
Direction of
rotation arrow