Pump does not work


Look for

Correction

1 Slow flashing Green Light

Clean Liquid Level Sensors.
Fill sink with water to proper level.
Tighten the External Wiring Harness on
back of Control Panel.

2 Solid Blue Light

Clean Liquid Level Sensors.
Drain sink and refill with proper water level.

3 Error LED on UPM

Record the pattern – See

“Error Codes”

4 Red, Green, Blue lights blinking together

Low power to UPM – See

“No Power”

5 No indicator lights at all

Water too hot – reduce temperatures to
115° with ice or cold water
See

“No Power”

Pump works- Heater does not work

Look for

Correction

1 Water temperature < 110°F

Check Heater and replace as necessary.
Check Triac(s) and replace as necessary.

2 Water temperature between 110°F and
120°F

Normal operating temperature.

3 Water temperature > 120°F

Check Thermistor and replace as necessary.
Too much soap can cause excessive heat
buildup


Water too hot or not hot enough

Look for

Correction

1 Water temperature < 110°F

Check Heater and replace as necessary.
Check Triac(s) and replace as necessary.

2 Water temperature between 110°F and
120°F

Normal operating temperature.

3 Water temperature > 120°F

Check thermistor and replace as necessary.
Too much soap can cause excessive heat
buildup.