E R R O R C O D E S
®
C O M B I T HE R M
In the event of an error code, the Combitherm may be operated on a limited basis. Error conditions under
which continued operation can be conducted are indicated by “Yes” in the chart shown below.
When the oven malfunctions, an error code will appear in the display.
PRESS THE START KEY TO ACKNOWLEDGE THE ERROR.
The keys that begin to flash represent operational modes that are still usable.
SELECT AND PRESS ONE OF THE COOKING MODES INDICATED.
The oven control will only respond to the mode keys that are flashing.
SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMAL CIRCUMSTANCES.
Depending on the error code involved, oven function, such as temperature range, may be limited.
PRESS THE START KEY TO BEGIN THE COOKING PROCESS.
PRESS THE START KEY WHEN THE TIMER EXPIRES.
When the oven fault is corrected, the Combitherm will return to normal Operation.
CONTINUED OPERATION UNDER ERROR CONDITIONS
E M E R G E N C Y O P E R A T I O N
Error
Code
Display Shows
ES
ESi
Steam
Mode
Combination
Mode
Convection
Mode
Rether m
Mode
E01
Low Water
Yes
No
No
No
To 365°F
No
E02
Control Temp High
Yes
Yes
Yes
To 284°F
To 284°F
To 284°F
E03
Fan Malfunction
No
No
—
—
—
—
E04
Aux Fan Fault
Yes
Yes
Yes
To 284°F
To 284°F
To 284°F
E11
Excess Oven Temp
Yes
Yes
No
No
No
No
E13
Excess Steam Gen Temp
Yes
No
No
No
No
No
E15
Excess Condensate Temp
Yes
Yes
No
No
To 356°F
No
E21
Oven Probe Fault
Yes
Yes
212°F only
No
No
No
E22
Core Temp Probe Fault
Yes
Yes
Yes
Yes
Yes
Yes
E23
Steam Gen Probe Fault
Yes
No
Yes
Yes
Yes
Yes
E24
Bypass Probe Fault
Yes
Yes
To 210°F
No
Yes
No
E25
Condensate Probe Fault
Yes
Yes
Yes
To 356°F
To 356°F
To 320°F
E26
Steam Gen Safety Probe Fault
Yes
No
Yes
Yes
Yes
Yes
E27
Excess Steam Gen Safety Temp
Yes
No
No
No
No
No
E29
Probe Short to Frame
Yes
Yes
No
No
No
No
E34
DE (Drain) Pump Failure
Yes
No
Yes
Yes
Yes
Yes
E35
Venting Error
Yes
Yes
Yes
Yes
Yes
Yes
E36
Steam Temp High
No
Yes
No
No
Yes
No
E80
ID Error
Yes
Yes
Yes
Yes
Yes
Yes
E81
Program Memory Error
Yes
Yes
Yes
Yes
Yes
Yes
E82
WP Error
Yes
Yes
Yes
Yes
Yes
Yes
E83
Algo Error
Yes
Yes
Yes
Yes
Yes
Yes
E96
Connection Error
Yes
Yes
No
No
No
No