Electrical grounding instructions, Avertissement – Alto-Shaam 12.18ESG User Manual
Page 16
An electrical wiring diagram is located behind the
control panel on the left side of the oven. This
appliance must be branch circuit protected with proper
ampacities, in accordance with the wiring diagram
located in the electrical compartment of the oven.
Wire size for the main incoming power to the unit
must match the minimum size listed in the
specifications applicable to the specific oven model.
For supply connections, locate the wire size posted on
the label located on the electrical control box cover,
behind the service panel.
Before operating the oven, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After both water and electrical connections
have been completed, operate the oven in
any cooking mode for a period of 15 minutes
and recheck the main power connections at
the terminal block to make certain they
remain tight.
G A S C O M B I T H E R M
—
I N S T A L L A T I O N M A N U A L
#MN-28898
PG
. 14
®
C O M B I T HE R M
E L E C T R I C A L & I N S TA L L AT I O N R E Q U I R E M E N T S
MODEL
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
KW
CIRCUIT
AWG
6•10esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
6•10esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
7•14esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
7•14esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
10•10esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
10•10esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
10•20esG
110-120
1
50/60
7.8
.936
20 A
2
WIRE
PLUS GROUND
AWG
12
12•18esG
110-120
1
50/60
7.8
.936
20 A
2
WIRE
PLUS GROUND
AWG
12
20•20esG
110-120
1
50/60
22.0
2.64
30 A
2
WIRE
PLUS GROUND
AWG
10
OTHER VOLTAGES AVAILABLE
: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
380-415V:
To prevent an electrical shock hazard
between the appliance and other appliances
or metal parts in close vicinity, an
equalization-bonding stud is provided.
An equalization bonding lead must be
connected to this stud and the other
appliances / metal parts to provide
sufficient protection against potential
difference. The terminal is marked with
the following symbol.
D A N G E R
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
D A N G E R
AVERTISSEMENT:
Directives
pour la prise de courant électrique Cet
appareil est muni d'une fiche à trios
branches (prise de Courant) afin de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fiche.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or