• Press the Channel button until the channel number to be calibrated is displayed
• Press and hold the Calibrate button while the channel number is still displayed
The DL-32 will either display a lower case ‘d’ to indicate the defaults have been restored for the
selected channel or an upper case ‘E’ to indicate that the restoration could not occur. Normally
an E indicates that more than .1V is being detected on the selected input.
12. External Solenoid Drivers
This feature is not supported in the initial firmware release of the DL-32. It will be supported in
future firmware releases.
13. Programming the DL-32 with LM Programmer
To connect the DL-32 for programming follow these steps:
1. Disconnect any devices plugged into the DL-32’s Serial IN port and restart the DL-32 by
switching it’s power off and back on.
2. Connect the 2.5mm to DB-9 computer interface cable into the Serial OUT port. Your
computer needs a serial port. If it does not have one, you will need a USB to serial
adapter.
3. Power the DL-32 either from 12V or a 9V.
4. Start the LM Programmer application
The following screen will show up: