- 22 -
• Connect the ground from the external sensor supply to the GND connection on the DL-32
• Connect the +5V from the external sensor supply to the ‘+’ input of the channel to be
calibrated
• Press the Channel button until the channel number to be calibrated is displayed
• Press and hold the Calibrate button while the channel number is still displayed
The DL-32 will either display a lower case ‘c’ to indicate the Calibration has occurred for the
selected channel or an upper case ‘E’ to indicate that the calibration could not occur. Normally
an E indicates that the voltage being input is .1V or more off from 5V.
11.1.3
Restoring a channel to factory calibration
In order to restore an external input back to the factory default calibration, the following steps
must be taken.
• Connect a jumper wire from the ‘+’ input of the channel to be restored to the GND
connection on the DL-32