Table: Baud Rate Settings
Baud Rate
1 (for POS 1)
2 (for POS 1)
3 (for POS 2)
4 (for POS 2)
2400
ON
ON
ON
ON
4800
OFF
ON
OFF
ON
9600
ON
OFF
ON
OFF
19200
OFF
OFF
OFF
OFF
7. Plug in the wall transformers for the Omega JR and the DBox(es) to the dedicated outlets.
8. Carefully following the vendor’s setup instructions, run the POS application. If the system fails
at this point, contact the vendor for additional instructions.
For the POS/Omega JR system to function properly, the POS must be programmed for the exact
number of dispensers to be controlled by the POS/Omega JR system. (An MPD has multiple
hoses, but is considered to be only two dispensers — one dispenser on either side.)