Check the valve components for wear and replace where

necessary. Every time valves are inspected, all

o-rings and valve covers should be replaced.

Reassemble the valve units and fit them

back in the fluid end. Valve cover screws

should be tightened with a torque wrench

set for 25.3 ft. lbs.

Should excessive scaling inside the fluid end hinder the

valve extraction open one of the two lateral inlet ports,

remove the three plugs, Fig. 15, insert our special tool

p/n F200000040 (or a corresponding one) and push the

valve unit out as shown in Fig. 15.