beautypg.com

Kez series, General pump – General Pump KEZ Owner Manual v.2 User Manual

Page 4

background image

Page 4

GENERAL PUMP

A member of the Interpump Group

KEZ SERIES

2. SYMBOL DESCRIPTIONS

Warning

Potential Danger

Danger

High Voltage

Danger

Wear protective mask

Danger

Wear goggles

Danger

Wear protective gloves

Danger

Wear protective boots

Read carefully and understand

the manual before operating

the pump

1. INTRODUCTION

This manual describes the use and maintenance

instructions of the KEZ pump, and should be carefully read

and

understood

before

using

the

pump.

Correct use and adequate maintenance will guarantee the

pumps trouble-free operation for a long time. General

Pump declines any responsibility for damage caused by

misuse or the non-observance of the instructions indicated

in this manual.

Upon receiving the pump, check that it is complete and in

perfect condition.. Should anything be found out of order,

please contact us before installing and starting the pump.

3. SAFETY

3.1 General Safety Indications

The misuse of pumps and high pressure units may cause

severe injury to people and/or damage to property. Anyone

requested to assemble or use high pressure units must

possess the necessary competence to do so, should be

aware of the characteristics of the components assem-

bled/used, and must adopt all the necessary precautions

in orter to guarantee maximum safety in any operating

condition. In the interest of safety, no precaution that is

reasonably feasible must be neglected, both by the

Manufacturer and the Operator.

3.2 High pressure unit safety requirements

1. The pressure line must always be equipped with a

safety valve.

2. High pressure unit components, in particular

for those units working outside, must be adequately

protected against rain, frost and heat.

3. The units electrical parts must be adequately

protected from water spray, and must comply with the

specific norms in force.

4. High pressure hoses must be correctly sized for the

units maximum operating pressure, and must only be

used within the pressure range indicated by the hose

manufacturer.

5. The extremeties of high pressure hoses must be

sheathed and fastened to a steady structure in order

to avoid dangerous whiplashes should they burst or

should their connections break.

6. Appropriate safety guards must be provided for the

pump transmission systems (joints, pulleys and belts,

auxiliary drives).

3.3 Safety During Operation

The working area of a high pressure system muste be

clearly signalled. Access must be prohibited to non-author-

ized personnel and, if possible, the area must be fenced

in. The personnel authorized to access this area must be

previously trained, and informed about the risks that may

arise from failures or malfunctions of the high pressure

unit.

Before starting the unit, the operator must check:

1. That the high pressure unit is correctly fed (see

paragraph 9.5).

Ref 300665 Rev.C

07-13