The pump pulses irregularly (knocking):(cont)

• The pump is not primed due to valve seizing

• Worn valves

• Worn pressure packings

• Incorrect operation of the pressure adjust

ment valve

• Transmission problems

The pump does not deliver the rated flow / is

noisy:

• Insufficient feeding (see the causes listed

above)

• RPM are less than the rated flow

• Excessive amount of water by-passed by the

pressure adjustment valve

• Worn valves

• Leakage from the pressure packings

• Cavitation due to:

1) Wrong sizing of the suction hose/

undersized diameters

2) Insufficient flow rate

3) High water temperature

Insufficient pump pressure:

• The nozzle (or has become)too large

• Insufficient RPM

• Leakage from the pressure packings

• Incorrect operation of the pressure adjust-

ment valve

• Worn valves

Overheated pump:

• The pump is overloaded (pressure or RPM

exceed the rated values)

• Oil level is too low, or the oil is not of a suit-

able type, indicated in Chapter 11 (see para-

graph 11.1.1)

• Excessive belt tension or incorrect alignment

of the joint or the pulleys

• Excessive inclination of the pump during

operation

Hose vibrations or knocking:

• Air suction

• Incorrect operation of the pressure adjust

ment valve

• Valve malfunction

• Irregular drive transmission motion