9.8 Delivery Line

To obtain a correct delivery line, please comply with the

following installation instructions:

1. The internal diameter of the pump must allow to guar

antee correct fluid speed; see digram in paragraph 9.9

2. The first section of the hose connected to the pump

must be flexible in order to isolate pump vibrations

from the rest of the system.

3. Use high pressure hoses and fittings that guarantee

wide safety margins in any working condition.

4. Install a safety valve on the delivery line.

5. Use pressure switches suitable for the pulsating loads

typical of plunger pumps.

6. In the design phase, take into proper account the

pressure drop along the line, since this causes a

reduction in usage pressure with respect to the value

measured at the pump.

7. If the pump pulsations are harmful for particular appli

cations, install an appropriately sized pulsation damp

ener on the delivery line.

9.9 Internal Diameter of the Hose Line

To determine the internal diameter of the hose, please

refer to the following diagram.

Suction Hose

With a flow rate of ~24 GPM (91 l/mn) and water speed of

0.5 m/sec. the diagram line that connects the two scales

intersects the central scale, indicating the diameters, at a

value of ~ 62 mm (2.4 inch).

Delivery Hose

With a flow rate of ~24 GPM (91 l/mn) and water speed of

5 m/sec. The diagram line that connects the two scales

intersects the central scale, indicating the diameters at a

value of ~ 19.5 mm (.77 inch).

Optimum speed values:

• Suction:

≤ 0.5 m/sec.

• Delivery:

≤ 5 m/sec.

Page 10

GENERAL PUMP

A member of the Interpump Group

KEZ SERIES

The diagram does not take into consideration the

pipe and valve resistance, drop in pressure, due

to the pipe length, the viscosity of the pumped

fluid, its temperature, etc.