14. PUMP STOPPED FOR LONG TIME
Before starting the pump for the very first
time after a long period from the date of
shipment check for the correct oil level,
check the valves as indicated in chapter
11 and then comply with the starting
procedures indicated in chapter 10. When
a long inactivity is scheduled drain the
entire suction and delivery line and then
run the pump dry only for a few seconds
in order to drain out the water collected
inside the fluid end.
15. PRECAUTIONS AGAINST FREEZING
Where and when there is a risk of freezing
the following pracautions should be taken:
-
After use drain the entire suction and delivery lines
(filter included) by means of discharging devices,
provided and positioned specifically for this purpose
along the lowest point of the lines.
-
Run the pump only for a few seconds in order to
drain the water collected inside the fluid end.
Or when applicable:
-
Add a recommended amount of anti-freeze into the
water tank and run the pump until the anti-freeze
works all through the system.
If a pump is frozen or appears frozen ON
NO ACCOUNT SHOULD THE PUMP BE
OPERATED until the entire
system has been thawed out.