Sender: Type in an alias of the switch in complete email address format, e.g.

[email protected]

, to

identify where the event log comes from.

Authentication: Tick the checkbox to enable this function, configuring the email account and

password for authentication (when Email Alert enabled, this function will then be available).

Mail Account: Set up the email account, e.g.

Tomadmin

, to receive the alert. It must be an existing

email account on the mail server, which you had set up in SMTP Server IP Address column.

Password: Type in the password to the email account.

Confirm Password: Reconfirm the password.

Rcpt e-mail Address 1 ~ 6: You can also assign up to 6 e-mail accounts to receive the alert.
• Click

.

Figure 3.17: SMTP Configuration



System Event Log—Event Configuration

When the Syslog/SMTP checkbox is ticked, the event log will be sent to system log server/SMTP server.
Also, per port log (link up, link down, and both) events can be sent to the system log server/SMTP server
with the respective checkbox ticked. After configuring, click ‘Apply’ to have the setting taken effect.

System event selection: There are 4 event types—Device cold start, Device warm start,

Authentication Failure, and X-ring topology change. Before you can tick the checkbox of each event
type, the Syslog Client Mode column on the Syslog Configuration tab/E-mail Alert column on the SMTP
Configuration tab must be enabled first.

¾

Device cold start: When the device executes cold start action, the system will issue a log

event.

¾

Device warm start: When the device executes warm start, the system will issue a log event.

¾

Authentication Failure: When the SNMP authentication fails, the system will issue a log event.

¾

X-ring topology change: When the X-ring topology has changed, the system will issue a log

event.