Chapter 2 installation, 1 led indicators – Advantech EKI-7657C User Manual
Page 20
EKI-7657C _Manual_ed1 10
Chapter 2
Installation
In this chapter, you will be given an overview of the EKI-7657C hardware installation
procedures.
2.1 LED
Indicators
There are few LEDs display the power status and network status located on the front
panel of EKI-7657C, each of them has its own specific meaning shown as below.
Table 2.1: EKI-7657C LED Definition
LED Color
Description
On
System power on
PWR Green
Off
No power input
On
The industrial switch is the master of the X-ring group
R.M. Green
Off
The industrial switch is not the master of the X-ring group
On
Power input 1 is active
PWR1 Green
Off
Power input 1 is inactive
On
Power input 2 is active
PWR2 Green
Off
Power input 2 is inactive
On
Power input 1 or 2 is inactive or port link down
(depends on Fault Relay Alarm configuration)
P-Fail Red
Off
Power input 1 and 2 are both active, or no power input
On
SFP port is linking
Flashing
Data is transmitting or receiving
Link/Active
(G7, G9, G10 SFP)
Green
Off
Not connected to network
On
The port is operating at speed of 1000M
Green
(Upper LED)
Off
The port is disconnected or not operating at speed of 1000M
On
Connected to network
Flashing
Networking is active
G7, G9, G10 (RJ-45)
Green
(Lower LED)
Off
Not connected to network
On
Connected to network
Flashing
Networking is active
Link/Active
(1 ~ 6 & 8)
Green
Off
Not connected to network
On
Ethernet port full duplex
Flashing
Collision of packets occurs
Duplex/Collision
(1 ~ 6 & 8)
Orange
Off
Ethernet port half duplex or not connected to network