Restoring power to synchrolinc – INSTEON SynchroLinc (2423A5) Manual User Manual
Page 8

SynchroLinc Owner’s Manual
Page 8 of 12
To Unlink from Scene 2:
1) If the Responder is a multi-scene device, tap the Scene button you wish to remove control from until
its LED illuminates
2) Set SynchroLinc to Linking Mode by pressing & holding the Set button until it beeps (3 seconds)
The SynchroLinc Status LED will begin blinking green
3) Set SynchroLinc to Unlinking Mode by pressing & holding the Set button until it beeps again (3
seconds)
The SynchroLinc Status LED will begin blinking red
4) Press & hold the Set button until it beeps a third time (3 seconds)
The SynchroLinc Status LED will begin blinking green
5) Press & hold the Set button until it beeps a fourth time (3 seconds)
The SynchroLinc Status LED will begin blinking red
You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.
6) Press & hold the Responder’s Set button for 3 seconds
SynchroLinc will double-beep and its Status LED will turn on solid green when the load is in its
high energy state and red when it is in its low energy state
7) Confirm that Unlinking was successful by turning the load on and off
The Responder will no longer respond
Restoring Power to SynchroLinc
SynchroLinc stores all of its settings, such as Links to other INSTEON devices, with non-volatile memory.
Because settings are saved in this non-volatile memory, they will not be lost in the event of a power
failure.
Additionally, in the event of a power loss, SynchroLinc will not resend ON/OFF commands to the
INSTEON devices it is Linked to.
Resetting SynchroLinc to its Factory Default Settings
The factory reset procedure will clear SynchroLinc of all INSTEON Links.
NOTE: Resetting SynchroLinc does not remove the high/low energy states stored during calibration. To
reset the high/low energy states, see Calibrating SynchroLinc.
1) If you are using SynchroLinc to control any INSTEON devices, Unlink those devices from
SynchroLinc. See Unlinking an INSTEON Responder from SynchroLinc.
2) Unplug SynchroLinc for about 10 seconds
3) While holding down the Set button on SynchroLinc, plug it back in, making sure not to let up on the
Set button
SynchroLinc will beep and its Status LED will turn on solid green or red
4) Continue to hold down the Set button for 3 seconds and then release
After a few seconds, SynchroLinc will double-beep and its Status LED will switch colors