Tp series, Technical details, Resistance readings (ohms) pump weight – HOMA TP Series User Manual
Page 13: Approx. (lbs.)
TP Series
Installation, Operation & Maintenance Manual
Technical Details
The following is offered as a general guide to values and capacities commonly used.
Resistance Readings (ohms)
Pump Weight
230V 230V
460V
Approx. (Lbs.)
Model
HP/poles 1 Phase
3 Phase *
3 Phase *
U1 - U2 / U1 - Z2 U-V-W
U-V-W
TP28
0.9/1
2.0 7.8
3.8 14.6
45 #
TP30/50/53 1.6/2
1.9 6.3 4.1 14.5
75 #
TP30/49/50/53
2.4/2
1.9 5.8 3.1 11.3
75 #
TP50/53
2.3/4
1.9 5.9 3.2 13.6
100 #
TP50/53
3.8/2
1.7 3.5 2.1 7.9
99 #
TP50/53
3.5/4
0.3 0.4 1.7 5.7
99 #
TP50/53
5.4/2
0.9 2.2 1.2 3.8
99 #
TP70
2.2/4
2.6 5.0 7.5 14.2
88 #
*Values should be as indicated between any 2 power leads.
Note: Resistance values include 30’ cable, and should be within +/- 10% of above value.
Impeller Nuts
10mm 13.6 Ft. Lbs.
12mm 45 Ft. Lbs.
Pump model:
TP30/16
TP28
TP30-49/24
TP50-53/23
TP50-53/16
TP50-53/35
TP50-53/24
TP50-53/38
TP50-53/54
TP70
Pump Rotation Right hand (CW) looking down from top of motor, CCW looking at bottom of suction.
Seal Probes: TP pumps use a 12mm seal probe. Single wire probes are for non classified areas,
and 2 wire probes are for Hazardous areas.
Seal Chamber Oil: White Mineral Oil (Chevron Lubricating Oil FM 32, 46, 68)
Seal Oil Volume
Minimum Distance between 2 pumps
TP 30/49/50/53
1.6/2 & 2.4/2
.01L (.3L FM)
TP 28, 30 6”
TP 50/53
2.4/4 & 3.5/4
1.2L
TP 50/53 8”
TP 50/53
3.8/2 & 5.4/2
1.2L
TP 70 6”
TP 70
.6L
Note: TP28 does not have a separate oil chamber, but does use .5L inside of the motor
housing.
Seal Oil Level
With pump lying on its side and oil port at 12:00, measure from the top of housing with gasket in place, to the oil level.
TP 30/49/50/53
1.6/2 & 2.4/2
1” from top of housing to oil level
TP 50/53
2.4/4 & 3.5/4
1 ½” from top of housing to oil level
TP 50/53
3.8/2 & 5.4/2
1 ½” from top of housing to oil level
TP 70
1 ½” from top of housing to oil level
Pg. 13