beautypg.com

Crossover blocks – Biamp A4 User Manual

Page 198

background image

Nexia-Manual-A4

Note:

Index1 represents the filter band to be controlled. All-Pass Filter bands are initially

numbered from left to right, and the selected band is displayed in the upper left hand corner of the
All-Pass Filter dialog screen in Nexia software. Use this number as Index1 for All-Pass Filter
strings.

Crossover Blocks

* Can contain a decimal number.

* Can contain a decimal number.

* Can contain a decimal number.

Notes:

2-way crossover:

Index1 = 1 is the low-pass filter cut-off frequency

Index1 = 2 is the high-pass filter cut-off frequency

3-Way crossover:

Index1 = 1 is low-pass filter cut-off frequency

Index1 = 2 is the lower slope of the mid filter cut-off frequency

Index1 = 3 is the higher slope of the mid filter cut-off frequency

Index1 = 4 is the high-pass filter cut-off frequency

184

This manual is related to the following products: