Biamp LTR User Manual
Page 10
8. Connect to network with Nexia software
Open Nexia software then connect to network.
File>Network>Connect to network
Close when complete
9. Assign IP address to Nexia device
All Nexia units ship from the factory with an assigned IP address of 192.168.1.101. When using more
than one device in a system, each device must have a unique IP address. Nexia device IP addresses
must be different from any PC IP address that will be used in this system.
File>Network>Perform Nexia Device Maintenance>Select desired Audia device>Set IP address
IP address should be 192.168.1.x (x=1-254)
Subnet mask should be 255.255.255.0
Default gateway should be 0.0.0.0
Click Ok when complete
Close Device Maintenance when complete
Note: To avoid conflict issues that occur when connecting multiple Nexia devices with the same IP
number, be sure to only connect one Nexia device at a time to the Ethernet switch when assigning IP
addresses.
10. Repeat steps 6-8 until all Nexia devices in system have been connected to network
and assigned a unique IP address.