beautypg.com

Audiafusion rear panel – Biamp AudiaFUSION User Manual

Page 10

background image

9

AudiaFUSION REAR PANEl

Channel-to-Channel Failover
In addition to entire amplifier failover, AudiaFUSION supports channel-to-channel failover, which is triggered by one of the following conditions:

Heat Sink alarm

Short Circuit alarm*

Channel Failure alarm

The wire failover link cable is not required when wiring channel-to-channel failover.

The redundant channel can be wired in parallel to the existing speaker line (shown above) or connected to a redundant speaker line.
The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered.

OUTPUT

Class 2 Wiring

AM-600

OUTPUT

Class 2 Wiring

AM-600

1

2

OUTPUT

Class 2 Wiring

AM-600

OUTPUT

Class 2 Wiring

AM-600

1

2

Primary

Redundant

Redundant Wiring

Parallel Wiring

* A Short Circuit alarm will cause failover only if the Persistent Short Circuit Delay time property in the AudiaFUSION is exceeded.