beautypg.com

Fill-Rite FR313 REMOTE PUMPS User Manual

Page 7

background image

7

Pump won’t prime

•Suction line problem

•Check for leaks in suction line.

•Bypass valve open

•Remove and inspect valve.

•Vanes sticking

•Check vanes and slots for nicks, burrs

or wear.

•Gasket leakage

•Tighten covers and joints.

•Excessive rotor or vane wear

•Check rotor and vanes for excessive

wear or damage.

•Motor not operating

•Rotor should turn clockwise (FR713) or

counterclockwise (303 & 313) at pump

end; if not, return for repair.

Pump hums but will

•Dirt in pump cavity

•Clean out pump cavity.

not operate

•Motor failure

•Motor bearing(s) frozen; return for repair.

Low capacity

•Excessive dirt in strainer

•Remove and clean strainer.

•Suction line problem

•Check for leaks in suction line.

•Bypass valve sticking

•Remove and inspect valve.

•Vanes sticking

•Check vanes and slots for wear.

•Excessive rotor or vane wear

•Check rotor and vanes for excessive

wear or damage.

Pump runs slowly

•Incorrect voltage

•Check incoming line voltage.

•Motor failure

•Motor bearing(s) failing; return for repair.

Motor stalls

•Bypass valve sticking

•Remove and inspect valve.

•Low voltage

•Check incoming line voltage.

•Excessive rotor or vane wear

•Check rotor and vanes for excessive

wear or damage.

Motor overheats

•Pumping high viscosity fluids

•These fluids can only be pumped for

short periods of time.

•Clogged strainer

•Remove and clean strainer.

•Restricted suction pipe

•Remove and clean pipe.

•Motor failure

•Bearing(s) tightening up; return for repair.

Motor will not turn on

•No power

•Check incoming power source.

•Motor failure

•Return for repair.

Fluid leakage

•Bad O-ring

•Check all O-ring gaskets.

•Check valve not seated

•Make sure check valve or check valve

alternate is in place.

•Dirty seal

•Clean and reseat seal.

•Bad seal

•Replace seal.

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

SOLUTION

This manual is related to the following products: