4fr713 flow curve, 313 flow curve, Repair maintenance circuit breakers – Fill-Rite FR313 REMOTE PUMPS User Manual
Page 4: Model fr713, 303 flow curve
![background image](/manuals/329470/4/background.png)
0
5
10
15
20
25
30
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
4
FR713 FLOW CURVE*
Flow in GPM
Discharge Presssure (PSI)
0
5
10
15
20
25
0
2
4
6
8
10
12
14
16 18
20
22
A
X
B
X
Flow in GPM
Discharge Presssure (PSI)
313 FLOW CURVE*
A) 303 with 12' of 3/4" hose and manual nozzle.
B) 303 with 12' of 3/4" hose and automatic nozzle.
C) 303 with 12' of 3/4" hose, automatic nozzle, and FR305R
dispenser.
*Nominal flow curve for reference only. Based on 3 feet
suction lift. Actual flow rate may vary.
A
B X
X
A) FR713 with 12' of 3/4" hose and manual nozzle.
B) FR713 with 12' of 3/4" hose and automatic nozzle.
C) FR713 with 12' of 3/4" hose, automatic nozzle, and
FR305R dispenser.
*Nominal flow curve for reference only. Based on 3 feet
suction lift. Actual flow rate may vary.
REPAIR
MAINTENANCE
Circuit Breakers
Power to the unit should be supplied from a dedicated circuit
breaker, 20 amp for FR713 and 30 amp for 303 & 313. No other
equipment should be powered from this breaker. If two pumps
are supplied from one breaker, that breaker must be capable of
handling the load of both motors. Provision must be made to
break both legs of any AC circuit.
See remote dispenser installation instructions in the Owner's
Operation & Safety Manual for completing the installation.
To maintain UL listing, motors that need repair should be taken
to an authorized repair shop or returned to factory for service.
Pumps must be thoroughly flushed and drained before being
taken in for service.
To keep pump running at its best, periodically perform the
following procedures.
Model FR713:
1. Check strainer for dirt accumulation. To clean strainer,
remove strainer cover (item 20) and pull out screen (Item
22).
2. Remove rotor cover (item 15) and inspect vanes (item 9).
Vanes should be replaced after extensive wear to prevent
damage to pump.
Model 303 or 313:
1. Examine check valve screen for dirt accumulation. To
clean screen, remove check valve cover (item 17) and pull
out valve (item 19).
2. Remove rotor cover (item 6) and inspect vanes (item 9).
Vanes should be replaced after extensive wear to prevent
damage to pump.
C
X
X
C
0.0
5.0
10.0
15.0
20.0
25.0
30.0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
303 FLOW CURVE*
Discharge Presssure (PSI)
Flow in GPM
A
B
X
X
X
C
A) 313 with 12' of 3/4" hose and manual nozzle.
B) 313 with 12' of 3/4" hose and automatic nozzle.
C) 313 with 12' of 3/4" hose, automatic nozzle, and FR305R
dispenser.
*Nominal flow curve for reference only. Based on 3 feet
suction lift. Actual flow rate may vary.