I-View ATX-100V/ARX-100V/ARX-400V Multi-videos Transmission System User Manual
Page 2

7
Front Panel
Rear Panel
2
3
1
4
9
8
5
6
Remote Terminal
UTP cable
ARX-400V/100V RJ45
ATX-100V
or PTT-120V
or PTT-130V
Video
ARX-400V Function Description:
1.) Surge ground: As for “S “ surge suppression port connects to earth-ground by shorter than 10 feet 16AWG or thicker cable.
2.) Front panel screws: The screws for fixing front panel and RMP-219 (19” rack mount panel)
3.) Power indicator: To indicate the status power-on or power-off of ARX-400V.
4.) Gain dip switches: According to the cable category and distance, user may need to adjust this switch to get optimum video picture.
5.) BNC ports: To connect with BNC connector of monitor or DVR.
6.) Bright/Sharp adjusters: To adjust video’s quality with a monitor for remote camera’s video signal.
7.) 8 pin RJ-45 connector: To connect to ATX-100V or PTT-100V(S) /130V(S) /120V by UTP wire of category 2 to 5 or better. Refer
to the pin assignment as below:
8.) Impedance adjuster: To increase and restore original video signal.
9.) Power jack: Plug DC12V power supply.
Product Application Diagram and Installations
Using the ARX-100V to connect with ATX-100V at both Monitor and camera ends.
Using the ARX-100V to connect with PTT-100V(S) /130V(S)/120V at both Monitor and camera ends.
Using the ARX-400V to connect with PTT-100V/130V(S)/120V and ATX-100V devices at both DVR control and cameras ends