Midi data format – Yamaha PLG150-VL User Manual
Page 41
MIDI Data Format
41
RPN Data-entry
LSB
MSB MSB
parameter
Data Range
00H
00H
mmH
Pitch Bend Sensitivity
mm:00H-18H (0-+24)
Default:02H
01H
00H
mmH
Fine Tune
mm:00H-40H-7FH
(-64-0-+63)
Default : 40H 00H
02H
00H
mmH
Coarse Tune
mm:28H-40H-58H
(-24-0-+24)
Default : 40H 00H
7FH
7FH
—
Null
—
5. CHANNEL MODE MESSAGES
Cntrl#
parameter
Data Range
120
————
0
Terminates all sounds currently sounding. However, the status of channel messages are
maintained.
Cntrl#
parameter
Data Range
121
————
0
The values of the following controllers will be reset to the defaults.
Pitch Bend
Center
Channel Aftertouch
0
Modulation
0
Breath Control
Max
Foot Control
Max
Expression
Max
Control Change 13
Center
Hold 1
Off
Portamento
Off
Soft Pedal
Off
RPN
Null
Cntrl#
parameter
Data Range
123
————
0
Terminates all notes currently on. However, if Hold 1 is on, notes will continue sounding
for the time set previously.
Cntrl#
parameter
Data Range
124
————
0
Performs the same function as when an All Notes Off message is received.
Cntrl#
parameter
Data Range
125
————
0
Performs the same function as when an All Notes Off message is received. It will not acti-
vate OMNI ON.
Cntrl#
parameter
Data Range
126
Mono
0...16
Performs the same function as when an All Sounds Off message is received, and if the 3rd
byte (mono number) is in the range of 0 - 16, and sets the instrument to Mono Mode.
Cntrl#
parameter
Data Range
127
————
0
Performs the same function as when an All Sounds Off message is received, and sets the
instrument to Poly mode.
6. CHANNEL AFTERTOUCH
Status:
DnH
If the Part Parameter Rcv CHANNEL AFTER TOUCH = OFF, that Part will not receive
Channel After Touch Messages.
7. SYSTEM EXCLUSIVE MESSAGES
If the Part Parameter Rcv SYSTEM EXCLUSIVE = OFF, that Part will not receive Sys-
tem Exclusive Messages.
1)MIDI Master Volume(receive only)
F0H, 7FH, xnH, 04H, 01H, llH, mmH, F7H
xn : n=Device Number, xn=7F : Broadcast
ll : Master Volume LSB
mm : Master Volume MSB
When received, the Volume MSB will be effective for the System Parameter MASTER
VOLUME.
2)General MIDI System On (receive only)
F0H, 7EH, 7FH, 09H, 01H,F7H or F0H, 7EH, xnH, 09H, 01H, F7H
xn : n=Device Number
[VL70-m Native Format]
F0H, 43H, 1nH, 57H, ahH, amH, alH, ddH, ~, ddH, F7H
1n : n=Device Number
ah : Address High
am : Address Mid
al : Address Low
dd : Data
1) VL System Parameters
See