OPERATING INSTRUCTIONS 

Check and Fill the Fuel Hopper with Pellets: 

This Pellet Stove is available as a freestanding unit or as a fireplace insert.  There is a different method for filling 
the hopper for each type of heater: 

 To check and fill the hopper of the freestanding heater, simply lift the hopper door, visually check the hopper 

and add pellets when needed.   

 To check and fill the hopper of the insert heater, pull hopper lid forward, visually check the hopper and add 

pellets when needed. 

CAUTION: DO NOT OVERFILL THE PELLET FUEL HOPPER.  AS A SAFETY PRECAUTION, AUGER WILL NOT 
OPERATE AT ANY TIME WHEN FUEL HOPPER DOOR IS OPEN.
 

Pre‐start Check‐up: 

Make sure that all parts of the Pellet Stove Room Heater are cool before proceeding.  Remove the burn pot and 
clean out any ash debris. Be sure to re‐install the burn pot in the correct position (see page 29). 

The blowers and automatic fuel supply are controlled from a panel located on the right hand side of the stove. 

Note:  Your Pellet Stove may omit an odor as oil residue from the manufacturing process burns off and the high 
temperature  paint  cures.  You  can  minimize  this  effect  by  running  a  smaller  fire  for  the  first  few  hours  of 
operation.    Avoid  placing  any  items  on  the  stove  top  during  this  period  as  the  stove’s  paint  could  be 
permanently damaged. 

Lighting Instructions: 

ATTENTION:  Viewing  door  must  be  securely  latched  to  ensure  proper  stove  operation.    Push  door‐handle 
downward until latch is fully engaged; you will feel the latch engage and hear an audible click.
  

When first operating your Pellet Stove, depress the MODE button until the LED indicator above MANUAL lights up.  
This will engage MANUAL mode and provide you with full control of the heater’s control board functions and allow 
you to familiarize yourself with how the heater works.  The heat level for T‐STAT mode can only be set when the 
control is in the Manual Mode. 

Starting Up The Pellet Stove Room Heater: 

Whenever Operating the Pellet Stove for First Time, or if The Stove Runs Out Of Pellets, it is Necessary to Prime 
the Auger with Pellet Fuel.  To do this, Press and Hold the AUGER Button for Approximately 3 Seconds until the 
AUGER LED illuminates.  This Procedure will prime the Auger and then Automatically Initiate the Normal Ignition 
Cycle.   

CAUTION: Do not use this procedure for normal startup.  To do so would cause excessive fuel build‐up in the 
burn pot.
 

For  normal  startup  with  pellets  fuel  in  the  auger,  press  and  release  the  On/Off  button.  The  LED  indicator  light 
above the On/Off button will alternately flash green then red to indicate that the start‐up cycle has begun. The 
light above the Auger button will flash intermittently to indicate the activation of the auger feeding the pellets into 
the burn pot.  The electric igniter will also be activated at this time.  The igniter takes a few minutes to come up to 
temperature in order to ignite the pellets in the burn pot.  It will normally take between 4 minutes and 8 minutes 
for pellets to ignite.  

NOTE: If pellets do not ignite within 12 minutes the heater will shut down, requiring you to turn on the heater 
and repeat the start‐up process. 