MOBILE HOME INSTALLATION
Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280,
Part 24. Canadian installations require that the heater must be connected to a 3 or 4 inch, factory‐built chimney conforming
to CAN/ULC‐S629. See the installation illustrations in this manual for minimum height above the roof. U.S. Stove suggests the
use of Selkirk’s Pellet Venting Products. Refer to their installation instructions for proper installation of the exhaust and
combustion air intake. The chimney installation must allow for removal in case of mobile home transportation, especially
outside connections. You may contact your local building authority or person having jurisdiction on height restrictions.
In order for this unit to be installed in a mobile home the following criteria must be met:
The unit must be secured to the floor using lag bolts in the holes provided in the pedestal base.
Ensure that the unit is permanently electrically grounded to the chassis of your home.
IT IS MANDATORY TO TAKE THE COMBUSTION AIR FROM THE OUTSIDE WHEN INSTALLING THIS UNIT IN AIR TIGHT OR
MANUFACTURED/MOBILE HOMES.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTIANED. MAKE SURE TO MAINTAIN AN EFFECTIVE VAPOR BARRIER BY SEALING WITH SILICONE WHERE THE CHIMNEY OR
OTHER COMPONENTS PENETRATE TO THE EXTERIOR OF THE STRUCTURE. REFER TO AND FOLLOW THE CHIMNEY
MANUFACTURER’S INSTALLATION INSTRCUTIONS.
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
NOTE: Only the freestanding model is for installation into a mobile home.