beautypg.com

Installing your room heater ‐ continued – United States Stove Company PELLET 5660(I) User Manual

Page 18

background image

18 

INSTALLING YOUR ROOM HEATER ‐ continued 

FREESTANDING EXTERIOR VERTICAL INSTALLATION

 

 
1. Locate your Pellet Stove Room Heater in a location which meets the requirements of this manual, but 

in an area where it does not interfere with the house framing, wiring, etc. 

2.

Install a non‐combustible hearth pad underneath the pellet stove. This pad should extend at least 6” 
(152mm) in front of the unit.

 

3. Place your Pellet Stove Room Heater on the hearth pad and locate the unit in manner that will leave 

the exhaust vent with a minimum of 3” (75mm) clearance to any combustible wall. 

4. If installing the optional air intake, locate the center of the combustion air intake pipe at the back of 

your  unit.  Line  up  the  center  with  the  same  spot  on  your  exterior  wall  and  cut  a  2‐1/2”  (64mm) 
diameter hole through the wall. 

5. Secure  all  vent  joint  connections  with  3  screws.  Seal  the  exhaust  vent  joint  connections  with  high 

temperature silicone sealant.  

6. Locate the center of the exhaust pipe, at the back of the unit. Line up the center with the same spot 

on the exterior wall a cut a 7” (178mm) diameter hole through the wall. 

7. Install the wall thimble; (refer to the instructions which come with the wall thimble). 
8. Install an approved exhaust vent through the wall; be sure to make sure that 3” (75mm) clearances 

to combustibles are maintained. 

9. Secure  all  vent  joint  connections  with  3  screws.  Seal  the  exhaust  vent  joint  connections  with  high 

temperature silicone sealant. 

10. Install  a  Tee  with  a  cleanout  on  the  end  of  the  exhaust  pipe  and  then  install  approved  venting 

upward from there. Be sure to install support brackets every 5’ (1525cm) to keep the venting straight 
and secure. 

11. Extend the exhaust vent through the roof flashing and ensure that the vertical cap is approximately 

36” (900mm) above the roof. 

 