INTRODUCTION

Thank You for your purchase of a U.S. Stove Wood/Coal

Burning External Furnace. Your decision to buy our Clay-

ton Furnace was undoubtedly reached after much care-

ful thought and consideration. We are very proud you

chose this furnace and trust you will receive the comfort

and economy that others realize when heating with a U.S.

Stove product.
Your dealer is important in your experience with the fur-

nace not only with the purchase, but for recommen-

dations for professional installation for your home. The

qualified professional installer has been expertly trained

in solid-fuel furnace installation to assure the safety and

comfort for your family while saving you money. Trust your

experienced installer. They are specialist in this field.

Before installing and using your furnace, please read the

following pages thoroughly and carefully. If you follow the

instructions, your furnace will give you safe and more de-

pendable service for years to come.

• Check your local codes. This installation must

comply with their rulings.

• This is an outdoor hot air furnace and must NOT

be installed inside the home or a building.

• This furnace must be connected to a 110 volt

Ground Fault Circuit Interrupter (GFCI) outlet suit-

able for outdoor use.

• A back-up generator, 2,000 watts minimum, is

recommended in case of a power failure.

• Always have a properly functioning smoke or

ionization detector and a CO detector installed

in your home.

• To prevent injury or damage, do not allow any-

one who is unfamiliar with the furnace to operate

it.

• Spend adequate time with your furnace to be-

come well acquainted with the different settings

and how each will affect its burning patterns. It

is impossible to state just how each setting will

affect your furnace because of the variations in

each installation.

The BTU ranges and heating capacity specifications are

provided as a guide and in no way guarantee the output

or capacity of this unit. The actual BTU output depends

on the type of fuel being burned and its conditions, the

thermostat setting, the draft adjustment and the chimney

to which the unit is attached. The actual area that this

unit will heat depends on factors such as the conditions

of the building, heat loss, type of construction, amount of

insulation, type of air movement, the location of the unit

and more importantly the duct work and return air facility.

Warning:

Do not alter this appliance in any way other than speci-

fied in these instructions. Doing so may void your warranty.

Your 1600EF furnace comes ready for installation. No as-

sembly required. Unpack your furnace and insure that

there is no shipping damage. If damage exist, please

contact your dealer immediately. Review the items in-

cluded with your furnace located inside the firebox.
1 - 10” Starter Collar
1 - 12” Starter Collar for Cold Air Return
8 - #10 x 3/4 Screws w/ Sealing Washer
1 - Literature Package
This furnace may be installed as a Stand-Alone Central

Furnace or as a Supplementary Furnace. If installed as a

Central Furnace, this unit will have it’s own central ducting

system and will essentially be your primary heat source.

If installed as a Supplementary Furnace, the 1600EF will

assist an Electric, Gas or Oil Fired Furnace in heating your

home by utilizing the existing furnace’s duct work system.

The 1600EF

must not be wired in conjunction with the exist-

ing furnace. The outdoor furnace may be operated with

the supplied wall thermostat or a 24 volt thermostat that

you supply yourself.
The furnace should be placed outdoors on a level non-

combustible base, preferably a 4’ x 8’ concrete pad, as

close to the home as clearances to combustibles will al-

low. If locating the furnace more than 10 feet away from

the home, a minimum of 6 feet of Class “A” HT 2100 All

Fuel 6 inch chimney pipe is required -

Do not place the

furnace more than 40 feet away from the home. Maintain

all clearances stated in this manual.
Class “A” HT 2100 All Fuel 6” Chimney Pipe is recommend-

ed for optimum performance and can be purchased

from your local dealer. A Chimney Base Plate should

be installed over the flue outlet and sealed to maintain

weather resistance. A 2” clearance to combustibles must

be maintained from the pipe. We suggest using either

Simpson Dura-Vent or Metal Fab chimney products for

your installation.
If you choose to use single wall stainless, the flue temper-

atures will be reduced which promotes the formation of

creosote, possibly creating a fire hazard. If you use single

wall stainless pipe, the minimum clearance to combus-

tibles is 20”.
Attach the appropriate chimney pipe lengths to the cho-

sen chimney base plate and finish with a rain cap. Secure

the chimney with guy wires to each of the four anchors

point on the furnace. Your furnace requires it’s own chim-

ney system and can not share a flue with another appli-

ance.
Once you have selected a location for the furnace and

connected your furnace to a chimney and a 110 volt GFCI

outlet, you will need to commence an initial firing.

DO NOT

connect the furnace to your duct work at this time. Your

new furnace has a protective coating of oil and paint on

the surface which could produce smoke or odors during

the initial firing and will burn off.

Build a small fire - DO NOT

fill the firebox to it’s full capacity for the initial burn. This

initial firing allows the metals and castings to cure.
After completing the firing and allowing it to cool, you are

ready to finish the installation. Refer to the remainder of

this manual for detailed instructions.