Physical, Environment – National Instruments PCI-1411 User Manual
Page 30

Appendix A
Specifications
A-4
www.ni.com
Physical
Dimensions
PCI-1411..........................................10.7 by 17.5 cm
(4.2 by 6.9 in.)
PXI-1411 .........................................10 by 16 cm
(3.9 by 6.3 in.)
Weight
PCI-1411..........................................0.136 kg (0.3 lb.)
PXI-1411 .........................................0.154 kg (0.34 lb.)
Environment
Operating temperature ............................ 0–55 °C
Storage temperature ................................–20–70 °C
Relative humidity ...................................5–90%, noncondensing
MTBF .....................................................839,653 h at 30 °C
Emissions................................................EN 55011:1991 Group 1 Class A
at 10 m FCC Class A at 10 m
Functional shock (PXI only)...................MIL-T-28800 E Class 3 (per
Section 4.5.5.4.1) Half-sine shock
pulse, 11 ms duration, 30 g peak,
30 shocks per face
Operational random vibration
(PXI only) ...............................................5 to 500 Hz, 0.31 grms, 3 axes
Nonoperational random vibration
(PXI only) ...............................................5 to 500 Hz, 2.5 grms, 3 axes
Note
Random vibration profiles were developed in accordance with MIL-T-28800E and
MIL-STD-810E Method 514. Test levels exceed those recommended in MIL-STD-810E
for Category 1 (Basic Transportation, Figures 514.4-1 through 514.4-3).