Pci interface, Power requirements – National Instruments PCI-1411 User Manual
Page 29

Appendix A
Specifications
© National Instruments Corporation
A-3
PCI Interface
PCI initiator (master) capability............. Supported
PCI target (slave) capability................... Supported
Data path ................................................ 32 bits
Board voltage ......................................... 5 V, 12 V, –12 V
Board type .............................................. 32-bit half-size card
Parity generation/checking,
error reporting ........................................ Supported
Target decode speed............................... Medium (1 clock)
Target fast back-to-back capability........ Supported
Resource locking.................................... Supported as a master and slave
PCI interrupts ......................................... Interrupts passed on
INTA# signal
Base address registers ............................ BAR0 (16 KB)
BAR1 (64 KB)
Expansion ROM..................................... 4 KB
PCI master performance
Ideal ................................................ 133 Mbytes/s
Sustained ......................................... 100 Mbytes/s
Power Requirements
Voltage ................................................... + 5 V (1.00 A)
+12 V (75 mA)