Emulations – Printek 4503 User Manual
Page 82
IBM Proprinter Emulation
Page 4-22
Emulations
Select Software Interface n
ESC ESC
n
Selects the software interface n according to the table below.
n
Software Interface
0
Test (reserved for factory use)
1
ANSI X3.64 Emulation
2
Epson FX Emulation
3
Bar Code Mode (optional)
4
IBM Proprinter Emulation
5
DEC LA120 Emulation
6
TTY Emulation
7
Printek Emulation
?
Previously Selected Emulation
@
Default Emulation
Overrides the "Mode:" value in the "Setup: INTERFACE" menu. "Mode:
BarberPole" and "Mode: Hex Dump" cannot be overridden.
A numeric value for n may be specified in two different ways, with equivalent results:
a single byte with a value of 00 to 07 hex, or a single printable ASCII character "0" to
"7" (30 to 37 hex).
If more than one emulation has been selected, ESC ESC ? will return to the
previously selected emulation. This is particularly useful when the previous
emulation is unknown. Please beware that the memory (stack) is only one level deep.
ESC ESC @ will return to the default emulation, as specified by the "Mode:" value in
the "Setup: INTERFACE" menu.
This chapter describes IBM Proprinter emulation. If a different interface is selected,
the control codes and escape sequences described in this chapter will no longer be
applicable.
Example: The following escape sequences will select Printek emulation, load form
one, and then return to the previous emulation.
Escape Sequence:
ESC ESC
7
ESC
L
1
ESC ESC
?
Hexadecimal:
1B
1B
07
1B
4C
01
1B
1B
3F