Installation
(for qualified installers only)
2 1
Travis Industries
1 0 0 - 0 1 1 8 7 _ 0 0 0
4 0 7 0 2 1 9
Masonry Chimney Conversions (Interior or Standard)
•
Follow the requirements and use the equipment listed in the illustration below to install this appliance
into an interior masonry chimney.
•
Maximum vertical rise is 40'
•
Minimum vertical rise is 10'
•
The restrictor position should be set to the position that most closely resembles the vent
configuration (see "Approved Vent Configurations" for details). NOTE: because this installation
utilizes non-standard vent, the restrictor position may vary. Carefully monitor the burn characteristics
to verify correct restrictor position.
N O T E
:
Certain jurisdictions may not allow this type of installation or may require two co-linear vents be used for
venting through an existing masonry chimney. Check with your local building official before installing.
The entire chimney system must be
air-tight. Make sure to seal the
flashing, clean-out, and thimble
connection, and to inspect the
chimney.
4" Dia. Flex Line
(UL 1777 Gas Liner)
Co-Axial Straight
Lengths
#991 High Wind
Termination
#990 90° Elbow
Flashing (included in
#934 Masonry
Conversion Kit
Make sure the coaxial pipe
maintains a 1” clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
Connector with Cover
(included in #934 Masonry
Conversion Kit)
Freestanding Masonry Chimney
Standard Masonry Fireplace
Connector (included in #934
Masonry Conversion Kit)
secured and sealed to
block-off plate.
Flashing (included in
#934 Masonry
Conversion Kit)
#991 High Wind
Termination
The entire chimney system must
be air-tight. Seal the connector
cover and inspect the chimney.
Make sure the coaxial pipe
maintains a 1” clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
4" Dia. Flex Line
(UL 1777 Gas Liner)