Starting the scan and storing the scan result, Releasing locked channels, Multi-channel operation – Sennheiser EW100 G2 User Manual
Page 32: Adjusting the sensitivity (transmitters only)
32
Starting the scan and storing the scan result
̈
Before starting the scan, switch all transmitters of your system off, since
channels used by switched-on transmitters will not be displayed as “free
channels”.
̈
Select the “
SCAN
” menu.
̈
Select “
START
” and confirm your selection by pressing the
SET
button.
After the scan is completed, the number of free channels is displayed.
Pressing the
SET
button once more will store the scan result and lock all
channels that are used or subject to interference.
Releasing locked channels
̈
Select the “
SCAN
” menu.
̈
Select “
CLEAR
” and confirm your selection by pressing the
SET
button. All
channels in this channel bank can now be selected again.
Multi-channel operation
For multi-channel operation, only use the free channels in a channel bank.
Before putting the transmission links into operation, we recommend perfor-
ming an auto scan.
̈
Select a channel bank on a receiver.
̈
Scan this channel bank for free channels. If not enough free channels are
available in the selected channel bank, repeat the scan with another chan-
nel bank.
̈
Apply the scan result to all other transmitters and receivers.
Adjusting the sensitivity (transmitters only)
SENSIT
Via the “
SENSIT
” menu, you can adjust the modulation level of the transmit-
ters. This changes the transmitter’s input sensitivity.
The input sensitivity is adjusted too high when close talking distances, spea-
kers with loud voices or loud music passages cause overmodulation in the
transmission link. In this case, the SK 100 G2’s yellow LED (AF PEAK)
ᕤ
will
light up and the receiver’s level display for audio signal (AF) will show full
deflection (
see: „Modulation display of the receiving transmitter“ on
page 12
).
If, on the other hand, the sensitivity is adjusted too low, the transmission link
will be undermodulated, which would result in a signal with high background
noise.
The sensitivity is correctly adjusted when the level display for audio signal
“AF” shows full deflection only during the loudest passages.
EM 100 G2
Note:
For monitoring the adjusted sensitivity, the transmitter’s level display for
audio signal (AF) always indicates the audio level – even if the transmitter
is muted.
¿
EM 100 G2
EK 100 G2