Preparation

VENTILATION

WARNING: PROVIDE A FRESH AIR OPENING OF

AT LEAST THREE SQUARE FEET (2,800 SQUARE

CM) FOR EACH 100,000 BTU / HR RATING.

PROVIDE EXTRA FRESH AIR IF MORE

SPACE HEATERS ARE BEING USED. THE MINIMUM

VENTILATION REQUIREMENTS MUST BE

FOLLOWED TO AVOID RISKS ASSOCIATED WITH

CARBON MONOXIDE POISONING. MAKE

CERTAIN THESE REQUIREMENTS ARE MET

PRIOR TO OPERATING SPACE HEATER.

Example: A 200,000 Btu / Hr (58.6kw) space heater

requires one of the following:

• a two-car garage door [16 feet (4.88 meter) opening]

raised 5 inches (12.7 cm)

• a single-car garage door [9 feet (2.74 meter) opening]

raised 8 inches (20.3 cm)

• two, 30 inch (76.2 cm) windows raised 15 inches

(38.1 cm)

FUELS

WARNING: USE ONLY KEROSENE, #1/#2 DIESEL/

FUEL OIL, JET A OR JP8 FUELS TO AVOID RISK

OF FIRE OR EXPLOSION. NEVER USE GASOLINE,

OIL DRAINED FROM CRANKCASES, NAPHTHA,

PAINT THINNERS, ALCOHOL OR OTHER HIGHLY

FLAMMABLE FUELS.

Use only kerosene, #1/#2 diesel / fuel oil, JET A or JP-8 fuels.

Heavier fuels such as No. 2 fuel oil or No. 2 diesel fuel may

also be used but will result in:

• noticeable odor

• additional fuel filter maintenance

• the need for nontoxic, anti-icer additives in very cold

weather

Do not use fuels heavier than No. 2 grade or heavy oils such

as oil drained from crankcases. These heavy oils will not

ignite properly and will contaminate the space heater.

IMPORTANT: Use a KEROSENE ONLY (blue) or DIESEL

ONLY (yellow) storage container. Be sure storage container

is clean. Foreign matter such as rust, dirt, or water will cause

the ignition control assembly to shut down space heater.

Foreign matter may also require space heater’s fuel system

to be frequently cleaned.