AC SPECIFICATIONS

AC Characteristics

80L186EA13 80L186EA8

Symbol

Parameter

Min

Max

Min

Max

Units

Notes

INPUT CLOCK

13 MHz

8 MHz

T

F

CLKIN Frequency

0

26

0

16

MHz

1

T

C

CLKIN Period

38 5

%

62 5

%

ns

1

T

CH

CLKIN High Time

12

%

12

%

ns

1 2

T

CL

CLKIN Low Time

12

%

12

%

ns

1 2

T

CR

CLKIN Rise Time

1

8

1

8

ns

1 3

T

CF

CLKIN Fall Time

1

8

1

8

ns

1 3

OUTPUT CLOCK

T

CD

CLKIN to CLKOUT Delay

0

45

0

95

ns

1 4

T

CLKOUT Period

2 T

C

2 T

C

ns

1

T

PH

CLKOUT High Time

(T 2)

b

5

(T 2)

b

5

ns

1

T

PL

CLKOUT Low Time

(T 2)

b

5

(T 2)

b

5

ns

1

T

PR

CLKOUT Rise Time

1

12

1

12

ns

1 5

T

PF

CLKOUT Fall Time

1

12

1

12

ns

1 5

OUTPUT DELAYS

T

CHOV1

ALE LOCK

3

27

3

27

ns

1 4 6 7

T

CHOV2

MCS3 0 LCS UCS

3

32

3

32

ns

1 4

PCS6 0 RD WR

6 8

T

CHOV3

S2 0 (DEN) DT R

3

30

3

30

ns

1

BHE (RFSH) A19 16

T

CLOV1

LOCK RESOUT HLDA

3

27

3

27

ns

1 4 6

T0OUT T1OUT

T

CLOV2

RD WR MCS3 0 LCS

3

32

3

35

ns

1 4 6

UCS PCS6 0 INTA1 0

T

CLOV3

BHE (RFSH) DEN A19 16

3

30

3

30

ns

1 4 6

T

CLOV4

AD15 0 (A15 8 AD7 0)

3

34

3

35

ns

1 4 6

T

CLOV5

S2 0

3

38

3

40

ns

1 4 6

T

CHOF

RD WR BHE (RFSH)

0

27

0

27

ns

1

DT R LOCK
S2 0 A19 16

T

CLOF

DEN AD15 0
(A15 8 AD7 0)

0

27

0

27

ns

1

NOTES
1 See AC Timing Waveforms for waveforms and definition
2 Measured at V

IH

for high time V

IL

for low time

3 Only required to guarantee I

CC

Maximum limits are bounded by T

C

T

CH

and T

CL

4 Specified for a 50 pF load see Figure 13 for capacitive derating information
5 Specified for a 50 pF load see Figure 14 for rise and fall times outside 50 pF
6 See Figure 14 for rise and fall times
7 T

CHOV1

applies to BHE (RFSH) LOCK and A19 16 only after a HOLD release

8 T

CHOV2

applies to RD and WR only after a HOLD release

9 Setup and Hold are required to guarantee recognition
10 Setup and Hold are required for proper operation
11 T

CHOVS

applies to BHE (RFSH) and A19 16 only after a HOLD release

12 Pin names in parentheses apply to the 80C188EA 80L188EA

27

27

This manual is related to the following products: