beautypg.com

Command reference list – Integra PLA-50V1 User Manual

Page 47

background image

41

Command Reference List

CMD1

CMD2

LEN

01. Power ON

9FH

4EH

00H

02. Power OFF

9FH

4FH

00H

03. Input Switch Change

DFH

47H

01H

04. VOLUME Gain Data

DFH

7FH

03H

05. SCREEN MODE Select

DFH

51H

01H

06. AUDIO Mute On

9FH

3EH

00H

07. AUDIO Mute Off

9FH

3FH

00H

08. OSM Select

DFH

58H

01H

09. Color Gain Data

DFH

7FH

03H

10. TINT Gain Data

DFH

7FH

03H

11. SHARPNESS Gain Data

DFH

7FH

03H

12. CONTRAST Gain Data

DFH

7FH

03H

13. BRIGHT Gain Data

DFH

7FH

03H

14. Input MODE Request

1FH

41H

00H

15. RESET

1FH

54H

00H

16. COLOR TEMP SELECT

DFH

00H

01H

17. RED Gain Data

DFH

7FH

04H

18. GREEN Gain Data

DFH

7FH

04H

19. BLUE Gain Data

DFH

7FH

04H

20. VIDEO ADJ Request

1FH

45H

00H

21. Audio Select Set

DFH

70H

02H

22. Audio Select Request

1FH

6FH

00H

23. LONG LIFE Set

DFH

6BH

03H

24. Failure Mode Request

1FH

3FH

00H

01. Power ON

Function
The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH

80H

60H

4EH

00H

CKS

ACK
The plasma monitor returns the following ACK when the power is switched on.

3FH

60H

80H

4EH

00H

CKS

NOTE: Do not set the Power ON or Power OFF command
continuously.

02. Power OFF

Function
The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH

80H

60H

4FH

00H

CKS

ACK
The plasma monitor returns the following ACK when the power is switched off.

3FH

60H

80H

4FH

00H

CKS

NOTE: Do not set the Power ON or Power OFF command
continuously.

03. Input Switch Change

Function
The external control equipment switches the input of the plasma monitor.

Transmission Data

DFH

80H

60H

47H

01H

DATA00

CKS

DATA00 : Input Select 01H: Video1

02H: Video2

03H: Video3

05H: HD (HD1 or DTV or DTV1)

06H: HD2 (DTV2)

07H: RGB1/PC1

08H: RGB2/PC2

0CH: RGB3/PC3

ACK
The plasma monitor returns the following ACK when the input is switched.

3FH

60H

80H

47H

00H

CKS

04. VOLUME Gain Data

Function
The external control equipment changes the VOLUME gain data of the plasma
monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00 USER SOUND Gain Flag

05H

DATA01

VOLUME Gain Flag

01H

DATA02

VOLUME Gain

00H: Step 0

0AH: Step 10 (Default)

2AH: Step 42

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00 USER SOUND Gain Flag

05H

DATA01 VOLUME Gain Flag

01H

05. SCREEN MODE Select

Function
The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH

80H

60H

51H

01H

DATA00

CKS

DATA00

02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE (REAL)

ACK

7FH

60H

80H

51H

01H

DATA00

CKS

DATA00

02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE (REAL)