Command reference list – Integra PLA-50V1 User Manual
Page 47
41
Command Reference List
CMD1
CMD2
LEN
01. Power ON
9FH
4EH
00H
02. Power OFF
9FH
4FH
00H
03. Input Switch Change
DFH
47H
01H
04. VOLUME Gain Data
DFH
7FH
03H
05. SCREEN MODE Select
DFH
51H
01H
06. AUDIO Mute On
9FH
3EH
00H
07. AUDIO Mute Off
9FH
3FH
00H
08. OSM Select
DFH
58H
01H
09. Color Gain Data
DFH
7FH
03H
10. TINT Gain Data
DFH
7FH
03H
11. SHARPNESS Gain Data
DFH
7FH
03H
12. CONTRAST Gain Data
DFH
7FH
03H
13. BRIGHT Gain Data
DFH
7FH
03H
14. Input MODE Request
1FH
41H
00H
15. RESET
1FH
54H
00H
16. COLOR TEMP SELECT
DFH
00H
01H
17. RED Gain Data
DFH
7FH
04H
18. GREEN Gain Data
DFH
7FH
04H
19. BLUE Gain Data
DFH
7FH
04H
20. VIDEO ADJ Request
1FH
45H
00H
21. Audio Select Set
DFH
70H
02H
22. Audio Select Request
1FH
6FH
00H
23. LONG LIFE Set
DFH
6BH
03H
24. Failure Mode Request
1FH
3FH
00H
01. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH
80H
60H
4EH
00H
CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH
60H
80H
4EH
00H
CKS
NOTE: Do not set the Power ON or Power OFF command
continuously.
02. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH
80H
60H
4FH
00H
CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH
60H
80H
4FH
00H
CKS
NOTE: Do not set the Power ON or Power OFF command
continuously.
03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH
80H
60H
47H
01H
DATA00
CKS
DATA00 : Input Select 01H: Video1
02H: Video2
03H: Video3
05H: HD (HD1 or DTV or DTV1)
06H: HD2 (DTV2)
07H: RGB1/PC1
08H: RGB2/PC2
0CH: RGB3/PC3
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH
60H
80H
47H
00H
CKS
04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00 USER SOUND Gain Flag
05H
DATA01
VOLUME Gain Flag
01H
DATA02
VOLUME Gain
00H: Step 0
0AH: Step 10 (Default)
2AH: Step 42
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00 USER SOUND Gain Flag
05H
DATA01 VOLUME Gain Flag
01H
05. SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH
80H
60H
51H
01H
DATA00
CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE (REAL)
ACK
7FH
60H
80H
51H
01H
DATA00
CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE (REAL)