beautypg.com

External control – Integra PLA-50V1 User Manual

Page 45

background image

39

External Control

Application

These specifications cover the communications control of
the plasma monitor by external equipment.

Connections

Connections are made as described below.

plasma monitor

External equipment
e.g., Personal computer

1) Connector on the plasma monitor side: EXTERNAL

CONTROL connector.

Type of connector: D-Sub 9-pin male

No.

Pin Name

1

No Connection

2

RXD (Receive data)

3

TXD (Transmit data)

4

DTR (DTE side ready)

5

GND

6

DSR (DCE side ready)

7

RTS (Ready to send)

8

CTS (Clear to send)

9

No Connection

1

5

9

6

2) Connector on the external equipment side: Serial port

(RS-232C) connector.
See the specifications of the equipment that is to be
connected for the type of connector and the pin
assignment.

3) Wiring

Use a crossed (reverse) cable.
Wire the cable so that each pair of data lines cross
between the two devices. These data line pairs are RXD
(Receive data) and TXD (Transmit data), DTR (DTE
side ready) and DSR (DCE side ready), and RTS (Ready
to send) and CTS (Clear to send).

Communication Parameters

(1) Communication system

Asynchronous

(2) Interface

RS-232C

(3) Baud rate

9600 bps

(4) Data length

8 bits

(5) Parity

Odd

(6) Stop bit

1 bit

(7) Communication code

Hex