Ab a b, Water connection, Installing the water tank – InSinkErator Chilled Water Tank & Cold Only Faucet CWT-00 User Manual
Page 5
A
B
A
B
Property Damage: Join remaining tube
to cold water supply only. Water supply
valves must not prevent backward flow.
3
■
■
Install a T-fitting (not included)
onto the cold water supply line.
■
■
Install dedicated water control valve
with 3/8" compression fitting.
■
■
Install brass nut, ferrule and tube insert
on to white 3/8" tube which runs from
filter or “Y” quick-connect fitting.
■
■
Insert the white 3/8" tube into the 3/8"
compression fitting and tighten.
WATER CONNECTION
Brass Nut
Ferrule
Brass Insert
From filter or
water supply
White Tape
From filter or
water supply
To chilled water
tank “Inlet”
To hot water
dispenser
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
Follow these steps for installing chilled water tank with instant hot/cool water dispenser.
Property Damage: All tubes must be cut
squarely with no burrs.
2
■
■
Attach supplied quick connect elbow to
end of supplied white 1/4" tube.
■
■
Attach quick connect elbow to water
Inlet on front of chilled water tank.
■
■
Measure distance from water inlet on
chilled water tank to water supply valve
(See Step 3). Carefully trim white 1/4"
tube, allowing ample slack in tubing.
INSTALLING THE WATER TANK
■
■
Attach supplied quick connect elbow to
end of supplied blue 1/4" tube.
■
■
Attach quick connect elbow with blue
tube to water Outlet on front of chilled
water tank.
■
■
Measure distance from the chilled
water tank outlet to water supply line
on faucet. Carefully trim blue tube to
correct length.
■
■
Using quick connect elbow, connect
remaining end of blue tube to unmarked
copper tube coming from faucet.
White Tape
Inlet
Property Damage: Do not pinch or break tubing.
Do not distort the last 1 inch of tubing.
Pull on connection to ensure fully engaged.
■
■
Remove existing “Y” quick-connect
fitting and discard.
■
■
Connect white 3/8" tube from the
filter or water supply into the supplied
“Y” quick-connect fitting until it stops.
■
■
Insert 1/4" white tube from tank inlet
into the 3/8" to 1/4" quick-connect fitting.
■
■
Identify copper HOT water tube,
which is marked with white tape.
Install that tube into the 3/8" to 1/4"
quick-connect fitting.
5