beautypg.com

Installation - model ihf075 – IPSO CHM2172N User Manual

Page 15

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Washer-Extractors

14

5-08-53

Installation - Model IHF075

Ground

The machine must be placed on a flat, solid surface

(metal base, concrete or solid ground). It is

recommended that the machine be anchored on the

provided places (1) in the base, especially in case of a

plinth. Refer to Figure 9.

Figure 9

The machine must be placed entirely level. For easy

maintenance it is recommended to keep a minimal

distance of 23.62 in. (600 mm) between the wall and

the back of the machine.
If several machines are placed next to each other, there

should be a minimal distance of 1.18 in. (30 mm)

between each machine.

Electrical Installation Requirements
- Model IHC075

Table 2

CHM2180N

1

Mounting Bolt Holes

1

Machine with steam heating or boiler fed

machines without additional electrical heating

220V 3AC

380V 3AC + N

16 A

16 A

Machine with electrical heating

220V 3AC

380V 3AC + N

18 kW

50 A

32 A

21 kW

N/A

40 A

24 kW

N/A

40 A

30 kW

N/A

50 A