Moxa Technologies NPort 5600 User Manual
Page 40
NPort 5600 Series User’s Manual
Configuring NPort Administrator
5-10
Serial Parameters
ATTENTION
Check the serial communication parameters in your Serial Device’s user’s manual. You should
set up NPort’s serial parameters with the same communication parameters used by your serial
devices.
Baudrate
Setting
Factory Default
Necessity
50 bps to921.6 Kbps
115.2 Kbps
Required
Data bits
Setting
Factory Default
Necessity
5, 6, 7, 8
8
Required
When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.
Stop bits
Setting
Factory Default
Necessity
1, 1.5, 2
1
Required
Stop bits will be set to 1.5 when Data bits is set to 5 bits.
Parity
Setting
Factory Default
Necessity
None, Even, Odd, Space, Mark
None
Required
Flow control
Setting
Factory Default
Necessity
None, RTS/CTS, DTR/DSR, Xon/Xoff
RTS/CTS
Required
FIFO
Setting
Factory Default
Necessity
Enable, Disable
Enable
Required
NPort’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO
setting when your serial device does not have a FIFO to prevent data loss during communication.
Interface
Setting
Factory Default
Necessity
NPort 5610-16/8: RS-232 only
RS-232 only
Required
NPort 5630-16/8: RS-422/485 only
4-wire RS-485
Required
NPort 5650-16/8
RS-232
Required