29

ENGLISH

AMP

Power Output ........30 W + 30 W (6

THD=10%)

THD (Total Harmonic Distortion)

............................0.22% (15 W output 6

)

Input Sensitivity and Impedance...............200 mV
Frequency Response

.......................20 Hz-90 kHz/( –3 dB /Line)

Tone Control....... +8 dB, –8 dB, 100 Hz – 10 kHz
Speaker Impedance ................................... 6–8

FM

Tuning Frequency Range

........................87.5–108 MHz 50 kHz step

Usable Sensitivity .......................2.2 µV (75

IHF)

S/N Ratio.............................Stereo 68 dB (IHF-A)

....................................Mono 69 dB (IHF-A)

THD (Total Harmonic Distortion)

...................................Stereo 0.3% (1 kHz)

.....................................Mono 0.2% (1 kHz)

Frequency Response

.................30 Hz–15 kHz/+1.5 dB, –1.5 dB

Stereo Separation .......................... 40 dB (1 kHz)

AM

Tuning Frequency Range

........................... 522–1611 kHz 9kHz step

Usable Sensitivity ..................................... 320 µV
S/N Ratio .................................................... 45 dB
THD (Total Harmonic Distortion) ................1.00%

DAB

Tuning Frequency Range

................174.928–239.200 MHz (BAND3)
............1452.96–1490.624 MHz (L–BAND)

Frequency Response ........ 42 Hz-16 kHz ±0.5dB
THD (Total Harmonic Distortion) ................0.06%

SPECIFICATIONS & DIMENSIONAL DRAWINGS

STANDBY

STANDBY

PHONES

PHONES

POWER ON / STANDBY

POWER ON / STANDBY

CD RECEIVER CR601

CD RECEIVER CR601

PUSH TO ENTER

PUSH TO ENTER

VOLUME

VOLUME

TREBLE

TREBLE

BASS

BASS

INPUT

INPUT

MENU

MENU

DIRECT

DIRECT

12

336

12

312

210

(mm)

5

141

146

Band III (174 to 240 MHz)

Frequency

Level

174.928 MHz
176.640 MHz
178.352 MHz
180.064 MHz
181.936 MHz
183.648 MHz
185.360 MHz
187.072 MHz
188.928 MHz
190.640 MHz
192.352 MHz
194.064 MHz
195.936 MHz
197.648 MHz
199.360 MHz
201.072 MHz
202.928 MHz
204.640 MHz
206.352 MHz

5A
5B
5C
5D
6A
6B
6C
6D
7A
7B
7C
7D
8A
8B
8C
8D
9A
9B
9C

Frequency

Level

208.064 MHz
209.936 MHz
211.648 MHz
213.360 MHz
215.072 MHz
216.928 MHz
218.640 MHz
220.352 MHz
222.064 MHz
223.936 MHz
225.648 MHz
227.360 MHz
229.072 MHz
230.784 MHz
232.496 MHz
234.208 MHz
235.776 MHz
237.488 MHz
239.200 MHz

9D

10A
10B
10C
10D
11A
11B
11C
11D
12A
12B
12C
12D
13A
13B
13C
13D
13E
13F

L-Band (1452 to 1490 MHz)

Frequency

Level

1452.960 MHz
1454.672 MHz
1456.384 MHz
1458.096 MHz
1459.808 MHz
1461.520 MHz
1463.232 MHz
1464.944 MHz
1466.656 MHz
1468.368 MHz
1470.080 MHz
1471.792 MHz

LA
LB
LC
LD
LE
LF

LG
LH

LI

LJ

LK

LL

Frequency

Level

1473.504 MHz
1475.216 MHz
1476.928 MHz
1478.640 MHz
1480.352 MHz
1482.064 MHz
1483.776 MHz
1485.488 MHz
1487.200 MHz
1488.912 MHz
1490.624 MHz

LM

LN
LO
LP
LQ
LR
LS

LT

LU
LV

LW

OTHERS

The section describes the care and maintenance tasks that must be performed to optimize the operation of
your Marantz equipment.

7 Cleaning of equipment external surfaces

The exterior finish of your unit will last indefinitely with proper care and cleaning, Never use scouring pads,
steel wool, scourging powders or harsh chemical agents (e.g., lye solution), alcohol, thinner, benzine,
insecticide or other volatile substances as these wil mar the finish of the equipment. Likewise, never use
cloths containing chemical substances. If the equipment get dirty, wipe the external surfaces with a soft,
lint-free cloth.
If the equipment becomes heavily soiled:

• dilute some washing up liquid in water, in a ratio of one part detergent to six

parts water.

• dip a soft, lint-free cloth in the solution and wring the cloth till it is damp.

• wipe the equipment with the damp cloth.

• dry the equipment by wiping it with a dry cloth.

7 Repairs

Only the most competent and qualified service technicians should be allowed to service the factory-
trained warranty station personnel have the knowledge and special facilities needed for repair and
calibration of this precision equipment. After the warranty period has expired, repairs will be performed for
a charge if the equipment can be returned to normal operation.
In the event of difficulty, refer to your dealer or write directly to the nearest location to you that is listed on
the Marantz Authorized Service Station list. If writing, please include the model and serial number of the
equipment together with a full description of what you think is abnormal about the equipment's behaviour.

CD

Frequency Response ........20 Hz–20 kHz (±1 dB)
Audio Dynamic Range.................................93 dB
THD (Total Harmonic Distortion) ................0.01%
Wow and Flutter

................Below threshold of measurability

Audio Output/Impedance (Analog)

........................................1.3 V (rms) /1 k

S/N Ratio .....................................................93 dB

General

Power Supply ..............................AC 230V, 50 Hz
Power Consumption .....................................74 W
Stand-by Power Consumption.....................0.8 W
Dimensions (W x H x D)

........................210 W x 146 H x 336 D mm

Weight .........................................................5.7 kg

* Specifications subject to change without prior

notice.