beautypg.com

Multi-Tech Systems FR111 User Manual

Page 48

background image

48

The Be is supplied by your network service provider at the time
the trunk was provisioned.

When you have entered your Be, the Trunk Configuration menu is
displayed.

10 From the Trunk Configuration menu, enter option 7 Management

Type and the Management Type menu is displayed.

Management Type

1 - Annex D (ANSI T1.617)
2 - LMI
3 - Annex A (ITU-T Q.933)
P - Previous Menu

Selection : _

Enter the number that corresponds to the Management Type for
your trunk. The Management Type is supplied by your network
service provider at the time the trunk was provisioned.

Options 8 thru 11 modify the management protocol between the
MultiFRAD and the network switch. For most applications, the
default values should be adequate. If you do not need to change
any of them, proceed to step 15.

11 From the Trunk Configuration menu, enter option 8 Polling

Interval and the Polling Interval menu is displayed.

Enter the Polling Interval, in units of seconds.
Valid values are between 5 and 30 seconds.

x - Enter Number, or
P - Previous Menu

Selection : _

Enter the number of seconds for a polling cycle (i.e., the time
period between each status enquiry message sent from the
MultiFRAD).

12 From the Trunk Configuration menu, enter option 9 Full Status

Counter and the Full Status Counter menu is displayed.