beautypg.com

Cd code cd-r code, Function – Marantz CDR510 User Manual

Page 53

background image

- 53 -

CTS/RTS hardware flow control

Typical Host
RTS send

CDR510
CTS out

Not Busy
(Normal)

Busy

H

L

H

L

Timing chart

RTS

CTS

RxD

TxD

Control commands:

The control command packets have a data length of
7~10 bytes. ASCII codes from 0x00 to 0x7f are used
to receive serial data. At the transmission end, take
steps to convert the ASCII codes into HEX data to set
the data in the data packets. CR (0x0d) is added as
the data packet delimiter.

Example: Scroll command (ASCII code @12011)

@

1

2

0

1

1

CR

0x40

0x31

0x32

0x30

0x31

0x31

0x0d

When transmitting commands consecutively, put more
than 100ms blank between commands.

Status data transmission:

The status data packets have a fixed data length of 8
bytes. ASCII codes from 0x00 to 0x7f are used to
transmit serial data. For this reason, the ASCII codes
are converted into HEX data before the data is set in
the data packets and transmitted. CR (0x0d) is added
as the data packet delimiter.

Example: Transmission "Power ON" (ASCII code
@120PRON)

@

1

2

0

P

R

O

N

CR

0x40

0x31

0x32

0x30

0x50

0x57

0X4f

0x4e

0x0d

RC-5 Codes
Remote control Model RC330, (not supplied – available
from Marantz Professional) can control the CDR510
using these RC-5 codes. The CDR510 receives the
codes listed in the table below from the infrared remote
control sensor on the front of the unit and also the
REMOTE RC-5 IN/OUT jacks.

0 _ Space

20

00

26

00

1 ABC

20

01

26

01

2 DEF

20

02

26

02

3 GHI

20

03

26

03

4 JKL

20

04

26

04

5 MN

20

05

26

05

6 OPQ

20

06

26

06

7 RST

20

07

26

07

8 UVW

20

08

26

08

9 XYZ

20

09

26

09

PLAY

20

53

26

53

STOP

20

54

26

54

PAUSE

20

48

26

48

NEXT

20

32

26

32

PREVIOUS

20

33

26

33

FF

20

52

26

52

REW

20

50

26

50

PROGRAM

20

36

26

36

CANCEL/DELETE

20

49

26

49

SCROLL

20

11

26

11

AMS (intro scan)

20

43

26

43

TEMPO RESET

20

37

-

-

REC

-

-

26

55

OPEN/CLOSE

20

45

26

45

DISPLAY

20

15

26

15

ENTER

20

87

26

87

MENU/STORE

20

82

26

82

REPEAT

20

29

26

29

CD

20

63

-

-

CD-R

-

-

26

63

TR.INCR

-

-

26

114

CD code CD-R code

System (dec)

System (dec)

Command (dec)

Command (dec)

Function