10. Electrical Load Information
PNEG-338 Portable Dryer Installation Manual
27
1214S
1 PH 230V
Top Auger
5
26
252
148
350
C303B 100
Bottom Auger
5
26
C303B 100
(2) Fans
(2) 10 to 12
96
F614B 100
(2) Auxiliary
(2) 7.5
62
C330B *
3 PH 220V
Top Auger
5
13.2
176
92.4
225
C163B 60
Bottom Auger
5
13.2
C163B 60
(2) Fans
(2) 10 to 12
66
C366B 60
(2) Auxiliary
(2) 10
52
C303B *
3 PH 440V
Top Auger
5
6.6
93
46.2
150
C867A 60
Bottom Auger
5
6.6
C867A 60
(2) Fans
(2) 10 to 12
33
C180B 60
(2) Auxiliary
(2) 10
26
C163B *
1218S
1 PH 230V
Top Auger
5
26
252
148
350
100
Bottom Auger
5
26
100
(2) Fans
(2) 10 to 12
96
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
165
82.4
225
60
Bottom Auger
5
13.2
60
(2) Fans
(2) 10
56
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
87
41.2
150
60
Bottom Auger
5
6.6
60
(2) Fans
(2) 10
28
60
(2) Auxiliary
(2) 10
26
*
1220S
1 PH 230V
Top Auger
7.5
31
332
218
400
100
Bottom Auger
7.5
31
100
(2) Fans
(2) 10 to 17
156
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
7.5
20
235
118
300
90
Bottom Auger
7.5
20
90
(2) Fans
(2) 15
78
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
7.5
10
123
59
200
60
Bottom Auger
7.5
10
60
(2) Fans
(2) 15
39
60
(2) Auxiliary
(2) 15
39
*
1222S
1 PH 230V
Top Auger
7.5
31
332
218
400
100
Bottom Auger
7.5
31
100
(2) Fans
(2) 10 to 17
156
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
7.5
20
235
118
300
90
Bottom Auger
7.5
20
90
(2) Fans
(2) 15
78
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
7.5
10
123
59
200
60
Bottom Auger
7.5
10
60
(2) Fans
(2) 15
39
60
(2) Auxiliary
(2) 15
39
*
*Auxiliaries run through load and unload breakers.
Dryer
Model #
Voltage
Motor
HP
Fuel Load
Amps
Maximum Amps
with Auxiliaries
Minimum
Amps
Recommended
Service in Amps
Branch Breaker
in Amps