8. Fuel Connection

PNEG-338 Portable Dryer Installation Manual

19

Fuel System Specifications and Recommendations (LP) Liquid Propane

Natural Gas (N)

Gas Volume and Pressure

The dryer is designed to operate on natural gas having a heat value of approximately 1000 BTU per
cubic foot. The dryer is equipped with a natural gas supply pipe system connected to the heater solenoid
valves. A regulated pressure of 10 PSI must be provided at the connection to the dryer, with gas
available in sufficient volume to maintain the operating pressure.

Figure 8B Grain dryer connected to a natural gas supply tank.

Dryer

Model #

Maximum Heat

Capacity BTU Per Hour

Maximum Fuel Flow

Gals Per Hour

Fuel Line Size*

Heater Orifice Drill Size

1108

3,000,000

33

1/2''

1/4''

1110

3,500,000

38

1/2''

9/32''

1112

4,500,000

49

1/2''

21/64''

1114

5,750,000

63

1/2''

11/32''

1116

5,750,000

63

1/2''

11/32''

1118

6,750,000

74

1/2''

3/8''

1120

7,500,000

82

1/2''

25/64''

1122

8,750,000

96

3/4''

7/16''

1126

10,250,000

112

3/4''

29/64''

1214

6,200,000

68

3/4''

(U)9/32'' (L)7/32''

1216

7,200,000

79

3/4''

(U)21/64'' (L)7/32''

1218

7,200,000

79

3/4''

(U)21/64'' (L)7/32''

1220

8,500,000

93

3/4''

(U)11/32'' (L)1/4''

1222

9,750,000

107

3/4''

(1)3/8'' (1)1/4''

1226

10,500,000

115

3/4''

(1)25/64'' (1)1/4''

1314

8,100,000

88

3/4''

(3)7/32''

1318

8,100,000

88

3/4''

(3)7/32''

1322

8,100,000

88

3/4''

(3)7/32''

160AB

3,000,000

33

1/2''

1/4''

210AB

3,500,000

33

1/2''

1/4''

300AB

4,500,000

49

1/2''

21/64''

375AB

5,500,000

60

1/2''

21/64''

400AB

5,500,000

60

1/2''

21/64''

415AB

7,000,000

66

1/2''

(2)9/32''

600AB

9,000,000

98

3/4''

(2)21/64''

* Maximum line size for a 100' distance.

See fuel specifications chart on
Page 21

for required pressure and

typical maximum fuel flow rates.